Tools / Coax and twin-line impedance calculator

Coax and twin-line impedance calculator

Measure the conductors and enter the dielectric to find a cable's impedance, velocity factor and capacitance. Or enter the impedance you want, such as 75 Ω for a matching section, and get the size or spacing to use.

Under the braid, the diameter of the dielectric
Impedance––
Velocity factor–1 ÷ √εr
Capacitance––
Inductance–Per metre
Highest usable frequency––

Design for an impedance

Outer diameter for your inner conductor––
Inner diameter for your outer conductor––
The diagram updates as you change the values.

Coax impedance

The characteristic impedance of a coaxial line depends only on the ratio of its two diameters and the dielectric between them, not on its length:

Z0 = (138 ÷ √εr) × log₁₀(D ÷ d)
C = 55.6 × εr ÷ ln(D ÷ d) pF per metre

D is the inside diameter of the outer conductor (the outside of the dielectric) and d the diameter of the inner conductor. A 2.0 mm inner conductor in 7.0 mm of solid polyethylene, a ratio of 3.5, works out at 50 Ω and about 100 pF per metre, which is close to RG-213. Use the diameter of the dielectric for the outer conductor. A stranded inner conductor behaves like a solid one slightly thinner than its overall diameter, so measured stranded cables come out a few ohms low.

The calculator also gives the frequency where the cable stops behaving as simple coax because a second mode can travel in it. Well below that frequency is fine: for RG-213 it's well above 10 GHz, but for large hardline it can fall to a few GHz.

Twin line and ladder line

For two parallel round wires, the impedance depends on the ratio of their centre spacing to their diameter:

Z0 = (120 ÷ √εr) × arcosh(s ÷ d) ≈ (276 ÷ √εr) × log₁₀(2s ÷ d)

The exact arcosh form is used here, which matters when the wires are close together. Real ladder line has plastic spacers and insulation, so its effective permittivity is a little above 1. Window line sold as 450 Ω typically measures 360 to 400 Ω with a velocity factor of about 0.9. Open wire line with spreaders every metre or so is close to the air value.

Making your own line

Home-made lines are useful for matching sections, phasing lines and Q-sections. Copper tube inside copper pipe with PTFE spacers makes excellent low-loss air-spaced line for VHF and UHF, and two wires held apart by spreaders make open wire feeder for HF. After working out the dimensions, check the impedance with a NanoVNA: terminate the far end with a resistor of the expected impedance, and the input should read close to that value across the band. The coax stub calculator works out the length of a quarter-wave matching section.

Questions

How do I work out the impedance of coax?

Measure the inner conductor diameter and the diameter of the dielectric. Z0 = 138 ÷ √εr × log10(D ÷ d). For solid polyethylene, εr is 2.25.

What D/d ratio gives 50 Ω?

About 3.5 with solid polyethylene and 2.3 with air. For 75 Ω, about 6.5 with polyethylene and 3.5 with air.

What impedance is 450 Ω window line really?

Usually 360 to 400 Ω when measured, with a velocity factor of about 0.9, because the plastic web raises the effective permittivity.

Why is coax 50 Ω?

It's a compromise. Air-spaced coax has its lowest loss at about 77 Ω and handles the most power at about 30 Ω. 50 Ω balances the two.